SteriTec BD 121 Steri-Pak LF 121 Disposable Bowie-Dick Test

SKU
ZN180507-386
$6.00
In stock
Only 98 left
ZN180507-386 G11-5C

New in sealed small boxes. And pictures are from real stock. 

Here the price is for 1 small box sealed.

Made in 2015-10, expire on 2018-10

The buyer pays the shipping.

A Bowie-Dick Test Pack designed for daily monitoring of pre-vacuum steam sterilizers operating at 121°C for 11 minutes. Detects air leaks, inadequate steam penetration and vacuum pump failures.

  • Easy to interpret and printed on the box
  • Clear color change – blue-to-black
  • Lead-free and no toxic heavy metals
  • Recordable
  • Conforms to EN ISO 11140-4

INSTRUCTIONS FOR USE DF-188 Rev. D SteriTec Products Mfg. Co., Inc. Member of the Getinge Group 74 Inverness Drive East Englewood, CO 80112 USA www.getinge.com/steritec MEMBER OF THE GETINGE GROUP Indications for Use The Steri-Pak LF 121 Bowie-Dick Test Pack is designed for daily monitoring of pre-vacuum steam sterilizers operating at 121°C for 11 minutes with sub-atmospheric or trans-atmospheric cycles as defined in ISO 11140-4 to detect the presence of residual air. Color Change The indicator will change from blue to black when exposed to a steam sterilization cycle with acceptable vacuum cycles. Instructions for Use The Bowie-Dick test is conducted each day in an empty sterilizer prior to processing any loads. 1. Run a warm up cycle to properly heat the sterilizer. 2. Place the test pack on the bottom of the sterilizer nearest to the drain. The test pack should read “THIS SIDE UP” when placed correctly. 3. Run the sterilizer for 11 minutes at 121°C. 4. Remove the test pack from the sterilizer and allow the pack to cool. 5. Pull easy open zip tab across box front to open. 6. Remove indicator from the pack. If the indicator sheet is still warm upon removal from the pack, do not place it on a cold surface. The indicator may return to original color if a cold surface is encountered prior to indicator equilibration. Dispose of or recycle remaining pack materials. Interpretation 1. If the sterilizer is functioning properly, the indicator will show a uniform black color change throughout the entire pattern. 2. When a significant amount of residual air is present, the indicator shows a blue area in the center. 3. On rare occasions, bubbling of the laminate may occur. If this happens, analyze the card for appropriate color change as instructed above. Safety Precautions CAUTION: the test pack will be hot and should be opened carefully to avoid thermal injury. Storage • Store at normal room temperature 10° – 38°C and 10-70% R.H. • Store exposed indicator sheet away from light sources Expiry Date The expiry date is printed on the product packaging. Do not use after expiration date listed on the packaging. LOT Number A unique identification code, LOT , is printed on each indicator and packaging labels. Interfering Substances or Conditions There are no known interfering substances or conditions that could affect the intended use of the indicator or adversely affect the indicator performance. Release of Toxic Substances The indicator releases no known toxic substances in sufficient quantities to cause either a health hazard, or a hazard to the intended properties of the product being sterilized before, during or after the sterilization process. Declaration of Conformity The Steri-Pak LF 121 Bowie-Dick Test Pack indicator conforms to all applicable portions of ISO 11140-1 Type 2 indicators for use in specific tests and ISO 11140-4.

SKU ZN180507-386

No Other Seller Selling this Product